848

Fabric OS Message Reference

53-1003140-01

SPC-2044

5

SPC-2044

Message

S<slot number containing Encryption Engine>, <module name>: Read - device not open

<Device minor number>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the SPD device is not opened.

Recommended

Action

No action is required.

SPC-3001

Message

S<slot number containing Encryption Engine>, <module name>: No input KEK for DEK

inject, DEK: <DEK octet 1> <DEK octet 2> <DEK octet 3> <DEK octet 4>, KEK: <KEK

octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the wrapping key encryption key (KEK) for the data encryption key (DEK) to be injected does
not exist within the encryption engine CryptoModule.

Recommended

Action

For opaque key vaults such as DPM, recover the missing master key to the current or alternate position.

SPC-3002

Message

S<slot number containing Encryption Engine>, <module name>: No input KEK for DEK

rewrap, DEK: <DEK octet 1> <DEK octet 2> <DEK octet 3> <DEK octet 4>, KEK: <KEK

octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the input wrapping key encryption key (KEK) for the data encryption key (DEK) to be rewrapped
does not exist within the encryption engine CryptoModule.

Recommended

Action

For opaque key vaults such as DPM, recover the missing master key to the current or alternate position.