background image

712

Fabric OS Message Reference

53-1003140-01

PLAT-1009

5

PLAT-1009

Message

BladeSystem Chassis type requires setting maximum internal port speed to 8Gbps.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the chassis has an older midplane that cannot support 16 GFC internal ports.

This message occurs only on the Brocade 6548.

Recommended

Action

Install the switch in a newer chassis.

PLAT-1072

Message

The chassis is disabled because no Core Blades are available. Insert/replace one

or both Core Blades and run chassisenable.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the chassis has been disabled because of the unavailability of the core blades. There must
be at least one core blade in enabled state for the chassis to be considered ready. All core blades are
either missing, faulted, or powered off. This results in all logical switches (and ports) being disabled.

Recommended

Action

Make sure that all core blade slots have core blades inserted and their ejector switches are closed.
Power on core blades that are powered off, and power cycle or replace the core blades that are faulted.

Run the chassisenable command to re-enable the ports.

Running the fastboot or reboot command will also result in enabling the logical switches and ports.

Advertising