Bcm-1003, Bcm-1004, Bcm-1005 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 197

Advertising
background image

Fabric OS Message Reference

175

53-1003140-01

BCM-1003

5

BCM-1003

Message

An IPsec/IKE policy was deleted.

Message Type

AUDIT | LOG

Class

CFG

Severity

INFO

Probable Cause

Indicates that an Internet Protocol Security (IPsec) or Internet Key Exchange (IKE) policy was deleted
and the configuration file was updated.

Recommended

Action

No action is required.

BCM-1004

Message

Tape Read Pipelining is being disabled slot (<slot number>) port (<user port

index>) tunnel (<The configured tunnel ID (0-7)>).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Fabric OS version on the remote end of the tunnel does not support Tape Read
Pipelining.

Recommended

Action

No action is required.

BCM-1005

Message

S<slot number>,P<user port index>(<blade index>) [OID 0x<port OID>]: <string name

of ge>: port faulted due to SFP validation failure. Please check if the SFP is

valid for the configuration.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports (execute the sfpShow command on
each side to verify matched pair), the SFP transceivers have not deteriorated, and the Fibre Channel
cable is not faulty. Replace the SFP transceivers or the cable if necessary.

Advertising