background image

Fabric OS Message Reference

393

53-1003140-01

FCR-1048

5

Recommended

Action

No action is required.

FCR-1048

Message

On EX port (<port number>) setting port <credit type> credits failed.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates that the indicated credit type was not set. Setting port credits failed.

Recommended

Action

Send the First Failure Data Capture (FFDC) log to the support.

FCR-1049

Message

EX_Port (<port number>) received an ELP command that is not supported.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an incoming exchange link parameter (ELP) command that is not supported.

Recommended

Action

Use the portEnable and portDisable to enable or disable the port.

If the problem persists, contact your switch service provider.

FCR-1053

Message

Port <port number> was disabled, <disable reason>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port was disabled because of a mismatched configuration parameter.

Recommended

Action

Use the specified disable reason to identify a possible configuration parameter mismatch between the
EX_Port and the switch at the other end of the link.