153

53-1003140-01

ANV-1007

5

ANV-1007

Message

S<slot number>,C<chip index>: ANVIL PASS 1 low buff pool fault: <chip regval

field> 0x<chip error type>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that Anvil Pass 1 is running out of free buffers, which may cause chip fault.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

ANV-1008

Message

S<slot number>,C<chip index>: MAC-VID classifier table is full. No space for new

entry.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Media Access Control (MAC) VLAN ID (VID) classifier table is full and no more entries
can be added.

Recommended

Action

Delete some of the existing unused rules using the portcfg arp command and then add new entries.

ANV-1015

Message

Port reinitialized due to Link Reset failure on internal port S<slot

number>,P<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port is re-initialized due to link reset failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.