Fcr-1100, Fcr-1101, Fcr-1102 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 431

Advertising
background image

Fabric OS Message Reference

409

53-1003140-01

FCR-1100

5

FCR-1100

Message

16G EX_Port ICL topology for fabric <Fabric ID> is unbalanced.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the current configuration of the EX_Port inter-chassis link (ICL) paths are unbalanced.

Recommended

Action

Investigate the current EX_Port ICL configuration to ensure that all recommendations for cabling are
satisfied. Once cabling recommendations are satisfied, FCR-1101 message will be generated confirming
ICL paths are balanced.

FCR-1101

Message

16G EX_Port ICL topology for fabric <Fabric ID> is balanced.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the existing EX_Port inter-chassis link (ICL) configuration that was resulting in an
unbalanced topology for the corresponding fabric has been corrected.

Recommended

Action

No action is required.

FCR-1102

Message

ICL EX_Port <Port Numbers> need to be present in base switch to make a recommended

topology.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some of the ICL ports in a quad small form-factor pluggable (QSFP) are not present in the
base switch. Ideally, all ports in the QSFP group should be present in the base switch.

Recommended

Action

Move the specified ICL EX_Ports of the QSFP group into the base switch using the lscfg --config
command.