SEC-1154

5

SEC-1154

Message

PID change failed: <Reason> <defined status> <active status>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that either the defined or the active policy could not be updated. If the policy database is very
large, it might not be able to change the index/area because the new policy database exceeds the
maximum size. This message can also be caused when the switch is short of memory. The status values
can be either defined, active, or both. A negative value means that a policy set was failed by the daemon.

Recommended

Action

Reduce the size of the policy database.

SEC-1155

Message

PID change failed: <Reason> <defined status> <active status>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that either the defined or active policy was too large after modifying the index/area ID. The
status values can be either defined, active, or both. A negative value means that a policy set was failed
by the daemon.

Recommended

Action

Reduce the size of the specified policy database.

SEC-1156

Message

Change failed: <Reason> <defined status> <active status>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the security daemon is busy. The status values can be defined, active, or both. A negative
value means that a policy set was failed by the daemon.

Recommended

Action

For the first reject, wait a few minutes and then resubmit the transaction. Fabric-wide commands may
take a few minutes to propagate throughout the fabric. Make sure to wait a few minutes between
executing commands so that your commands do not overlap in the fabric.