Ficn-1063, Ficn-1064, Ficn-1065 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 453

Advertising
background image

Fabric OS Message Reference

431

53-1003140-01

FICN-1063

5

FICN-1063

Message

Egress Abort:Oxid=0x<the OXID of the aborted exchange>:Path=0x<VEPortNumber

HostDomain HostPort DeviceDomain><DevicePort LPAR CUADDR

DeviceAddr>:LastStates=0x<prior emulation state array><previous emulation

state><current emulation state>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an abort operation has been received from a peer FC interface for an active emulation
exchange.

Recommended

Action

This is an unexpected event; contact your vendor's customer support for assistance.

FICN-1064

Message

Ingress Abort:Oxid=0x<the OXID of the aborted exchange>:Unknown Path on

GEPort=<GEPortNumber> VEPort=<VEPortNumber> from SID=0x<Source Domain><Source

Port> to DID=0x<Destination Domain><Destination Port>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates an abort operation has been received from a local FC interface for an exchange.

Recommended

Action

If there were associated I/O errors at the same time as this event, contact your vendor's customer
support for assistance.

FICN-1065

Message

Egress Abort:Oxid=0x<the OXID of the aborted exchange>:Unknown Path on

GEPort=<GEPortNumber> VEPort=<VEPortNumber> from SID=0x<Source Domain ><Source

Port> to DID=0x<Destination Domain><Destination Port>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates an abort operation has been received from a peer FC interface for an exchange.

Recommended

Action

If there were associated I/O errors at the same time as this event, contact your vendor's customer
support for assistance.

Advertising