Ras messages, Ras-1001, Ras-1002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 750: Ras-1004

Advertising
background image

728

Fabric OS Message Reference

53-1003140-01

RAS-1001

5

RAS Messages

RAS-1001

Message

First failure data capture (FFDC) event occurred.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a first failure data capture (FFDC) event occurred and the failure data has been captured.

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

RAS-1002

Message

First failure data capture (FFDC) reached maximum storage size (<log size limit>

MB).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the storage size for first failure data capture (FFDC) has reached the maximum.

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

RAS-1004

Message

Software 'verify' error detected.

Message Type

LOG | FFDC

Severity

WARNING

Probable Cause

Indicates an internal software error.

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

Advertising