1.5 Instrument description

796 Titroprocessor, Instructions for use

12

12

The main page in expert user level.

ЪДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿

³ 2000-02-02 09:24:13 MAIN PAGE Titroprocessor 796 * ready * ³

³ ³

³ Method 3455.mth Chloride in Tap Water ³

³ ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД³

³ ³

³ ЪДДДДДДДДДД Application note ДДДДДДДДДДДДДДД¿³

³ User B. Miller ³ Chloride in Tap Water ³³

³ Run number 000 ³ ------------------------------------------³³

³ Statistics on 0 of 10 ³ Sample preparation: ³³

³ ³ ³³

³ Auto save on 1.7 % free ³ Pipet accurately 100.00 mL of sample in a ³³

³ Destination Data card ³ 150 mL beaker. ³³

³ Determ.name ³ ³³

³ ³ Reagent: c(HNO3)=2 mol/L Dos A2 ³³

³ Auto start on 1 of 10 ³ Titrant: c(AgNO3)=0,01 mol/L Dos A1 ³³

³ Silo on in# 12 out# 1 ³ Sensor : Ag-Titrode 6.0430.100 Ind A1 ³³

³ Changer 1 Sample pos. 1 ³ ³³

³ АДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДЩ³

³ ³

³ Ident1 Ident2 Ident3 Size Unit ³

³ Sample 001120/1 12 3455 100 mL ³

³ ³

³ Remark ³

³ ³

³ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ³

³ ³Config.³Load ³File ³ ³Edit ³Show ³Results³ ³Sample ³Devices³Common ³ ³

³ ³ ³method ³manager³ ³method ³curves ³ ³ ³silo ³ManCtrl³vars. ³ ³

³ АДДДДДДДБДДДДДДДБДДДДДДДЩ АДДДДДДДБДДДДДДДБДДДДДДДЩ АДДДДДДДБДДДДДДДБДДДДДДДЩ ³

АДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДЩ

The settings of the status area are the same as in the status window
(<STATUS>key). See below for details.

1.5.3 The status window

In the standard user level the status settings are available only in the status
window. The <STATUS> key on the keyboard will open the status window.

ЪДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿

³ 2000-02-10 14:04:05 MAIN PAGE 796 Titroprocessor * ready * ³

³ ³

³ Method Acid.mth Acid titration c(HCl)=0.1 mol/L ³

³ ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД³

³ ³

³ ЪДДДДДДДДДД Application Note ДДДДДДДДДДДДДДД¿³
³ UseÚÄÄÄ

Status

ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿ ³³

³ ³ ³ ³³
³ ³ Run number

000

Determination name ³------³³

³ ³ ³te in ³³

³ ³ Sample silo on Next sample in silo line 1 ³th ³³

³ ³ Sample entry in silo line 1 ³ ³³

³ ³ ³ ³³

³ ³ Auto start on Current sample 0 of 9999 ³ ³³

³ ³ ³ ³³

³ ³ Statistics on Data records 0 of 2 ³ ³³

³ ³ ³ ³³

³ ³ Save determ. data on Destination Data card ³ДДДДДДЩ³

³ ³ Free Memory 1.6 % ³ ³

³ ³ ³ ³

³ Sam³ Sample changer 1 First rack position 1 ³ ³

³ ³ ³ ³

³ RemÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ QUIT ДЩ ³

³ ³

³ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ЪДДДДДДДВДДДДДДДВДДДДДДД¿ ³

³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³

³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³

³ АДДДДДДДБДДДДДДДБДДДДДДДЩ АДДДДДДДБДДДДДДДБДДДДДДДЩ АДДДДДДДБДДДДДДДБДДДДДДДЩ ³

АДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДЩ

Date and time

Instrument state

Method name and comment

Application note
and trace window

Status

Area

Sample data

Softkey bar