8. Command reference

796 Titroprocessor, Instructions for use

193

193

Dos. rate

Addition speed

0.01 mL/min…150 mL/min | max.

The maximum dosing speed depends on the cylinder size
of the buret used.

Buret cylinder

max. speed

1 mL

3 mL/min

2 mL

6 mL/min

5 mL

15 mL/min

10 mL

30 mL/min

20 mL

60 mL/min

50 mL

150 mL/min

A value up to 150 mL/min can also be entered for smaller
buret cylinders; however, when the method is carried out
the dosing speed will automatically be reduced to the
largest possible value. Whenever possible '

max' should

be selected, except for viscous reagent solutions.

Volume

Absolute volume

0…999.99 mL

When entering the absolute reagent volume please take
the capacity of the target vessel into account.

Fill. rate

Buret filling speed

0.01 mL/min…150 mL/min | max.

The filling rate set here applies to both a concluding auto-
matic filling after a titration and possible refilling during a ti-
tration. The maximum value for the filling rate depends on
the cylinder size of the buret used.

Buret cylinder

max. speed

1 mL

3 mL/min

2 mL

6 mL/min

5 mL

15 mL/min

10 mL

30 mL/min

20 mL

60 mL/min

50 mL

150 mL/min

A value up to 150 mL/min can also be entered for smaller
buret cylinders; however, when the method is carried out
the dosing speed will automatically be reduced to the
largest possible value. Whenever possible '

max' should

be selected, except for viscous reagent solutions for
which too rapid filling can cause a partial vacuum in the
cylinder (bubble formation!).