5.3 Determinations

796 Titroprocessor, Instructions for use

88

88

The status window should be similar to that shown below:

ЪДДД

Status

ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿

³ ³
³ Run number

000

Determination name 00012115.403 ³

³ ³

³ Sample silo on Next sample in silo line 1 ³

³ Sample entry in silo line 11 ³

³ ³

³ Auto start on Current sample 0 of 9999 ³

³ ³

³ Statistics on Data records 0 of 10 ³

³ ³

³ Save determ. data on Destination Internal ³

³ Free Memory 93.9 % ³

³ ³

³ Sample changer 1 First rack position 1 ³

³ ³

АДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД QUIT ÄÙ

[Sample silo]

To enter the sample data open the sample silo with the [Sample
silo]

softkey of the <SAMPLE>key.

ЪДДД Sample silo : NEW.slo ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿

³ ³

³ # Method Ident1 Ident2 Ident3 Size Unit ³

³ ДДД ДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДД ДДДДД ³

³ <> 1 ³

³ 2 ³

³ 3 ³

Now enter the sample data line by line. This can be done manually or
the sample weight can be transferred directly from a balance. In the
latter case the sample identifiers can be entered later by hand.

If the necessary method has already been loaded then leave the
'Method' column empty. An entry would have the effect that before the
silo line involved is processed the given method is loaded into the
working memory.

Further details about editing the sample silo can be found on page 92ff.

In order to indicate which sample should be processed place the field
cursor on the line containing the sample data of the first sample. Press
the [ >> >> ] softkey to display the second softkey bar. Use the
[<-- Out pointer]

softkey to set the silo output marker. This

always marks the next silo line to be processed with the '

<' character. It

is carried out again for each determination.

³ # Method Ident1 Ident2 Ident3 Size Unit ³

³ ДДД ДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДД ДДДДД ³

³ < 1 971120/1 12 3455 100 mL ³

³ 2 971120/1 12 3455 100 mL ³

³ 3 971120/2 15 3455 100 mL ³

If subsequently – possibly even as the sample series is being
processed – further sample data are to be transferred from the balance
to the Titroprocessor then set the silo input pointer to the next free silo
line. This is carried out in a similar way to setting the silo insert pointer
(softkey [--> In pointer]). The insertion mark '

>' is moved on by