Hypertherm Phoenix 8.0 User Manual

Page 317

Advertising
background image

Diagnostics

310

Outputs
This test allows the activation of all optically-isolated discrete outputs in the control. To
change the state of an output, select it with the PREV and NEXT keys and press the
SPACE key. The current state of each output, On or Off, is displayed next to the output
name. Below is an output screen with all of the outputs Off.

Warning: When you activate the control’s outputs manually, the machine, torch and
marker can move and the cutting device can activate.


You can change the name of outputs that are displayed with a white background. To
change the output name, use the Previous/Next arrow key to highlight an output and type
the new output name. The output can be connected to the control and used as
commanded in the part program. For example, the EIA M22 and M23 code will turn on
and off output 12.

Note: The number and name of the outputs depends on the control software and
hardware configurations.

Advertising