515

Serial Ports

Both of the serial ports that are provided are shipped in the RS-232C wiring
configuration. To change either port to an RS-422 configuration, you must change a
jumper setting on the Serial Isolation Board that is inside the CNC on the back panel.
Find the appropriate jumper for the desired port at the bottom of the board and move the
jumper from the RS-232C position to the RS-422 position. These positions are clearly
marked on the board.

Warning! Configure the port for RS-422 operation before connecting RS-422

compatible devises.

The serial ports in the CNC are specifically designed to operate with a standard nine-pin
serial port connector. Specifications for these ports are as follows:

Channel Type

Optically Isolated RS-232C or RS-422.

Information Code

ASCII

Baud Rate

User-selectable up to 115.2K baud.

Number of Start Bits

1

Number or Stop Bits

1

Word Length

User selectable 7 or 8 bits.

Parity

User-selectable None, Even or Odd.

Data Synchronization

XON (Control-Q) / XOFF (Control-S).

Time Out

User-selectable in one-second increments.

Transmit Delay

User-selectable in one one/hundredths of a second

increments.

Rear Panel Connector

IBM-PC/AT compatible 9-pin D-type female.

Control RS-232C DB-9 Pinout

Pin

Signal

Name

Description

1

Shield

Chassis

ground

2

TxD

Transmit data to external device

3

RxD

Receive data from external device

4

No

connection

5

Common

Ground

6

No

connection

7

No

connection

8

No

connection

9

No

Connection