Hypertherm Phoenix 8.0 User Manual

Page 339

Advertising
background image

Password Setups

332

Dual Tilting Rotator Mode
Defines the tilt rotator to use two tilt axes rather than a rotation axis and tilt axis for
rotational bevel cutting. The Tilt Rotator Installed must be selected for this feature.

Key Press Logging
Records key press and other related information in a daily log file. This log is intended
for use by Service Technicians when a fault occurs to help review events before the fault
occurs. When logging is enabled, the log file is saved to the hard drive so it can be
retrieved by transfer to a floppy diskette or USB memory. Usually this parameter is set
to NO.

Table Size
Enter a value for the active cutting area for the X and Y axis. These values limit the plate
size parameter in the cutting setup screen to the maximum size of the table.

THCs Installed
Defines the total number of Sensor THC axes assigned for operation at the control.


THC Installed On Axis / Analog
Defines the THC axis. Select the THC, which axis it is installed on, and the analog input
to use (arc voltage feedback).

Note: Refer to the Station Configuration and Sensor THC sections of this guide for
additional information on the setup and use of the Sensor THC.

Ignore Torch Collision During IHS
Allows the system to ignore input about a torch collision during the initial height sense
cycle. This may be helpful for some THC mechanics.

Command THCs Installed
Enables the Command THC serial link. For more information on this feature, refer to the
Command THC section of this guide. Shown in Type P mode only.

Advertising
This manual is related to the following products: