Hypertherm Phoenix 8.0 User Manual

Page 331

Advertising
background image

Diagnostics

324

not operating properly, or the machine is being commanded to move or accelerate faster
than it is capable.

To correct this problem:
• Increase the Skew Error Tolerance Setup parameter in the machine setups screen.

• Re-tune the system.
• Decrease the maximum machine speed or the acceleration rate setup parameters.

Need Station Selection
This message displays if the input for a station or process has not been activated.
Example: When cutting in Plasma mode, a Plasma 1 or Plasma 2 input may be required
to execute the selected Plasma cut process.

Buffer Time Out
This message displays if there is an instance where the motion buffer is full and cannot
record the data being saved. This error allows the operator to stop the motion, back up on
path to the last pierce and start over without a position error. This error should be
reported to the control vendor.

CNC Time Out
This is a general error that may appear if there is an instance when any buffer is full and
cannot record the data being saved. This error allows the operator to stop the motion,
back up on path to the last pierce and start over. This error should be reported to the
control vendor.

Unable to Find HASP
The HASP is a hardware protection key (dongle) that enables the software. If the HASP
is not installed, the control will not work. If this message appears and the hardware key
is in place, contact your control vendor for assistance.

Advertising