Hypertherm Phoenix 8.0 User Manual

Page 460

Advertising
background image

Program Codes

453

M17

Oxy Gas On

M18

Oxy Gas Off

M19

Cancel All Stations

M26

Station Select On

M27

Station Select Off

M28

CBH / Rotator(s) Disable

M29

CBH / Rotator(s) Enable

M30

End of Program (same as M02)

M31

Reset Functions (Cut Off, Marker Off, Kerf Off)

M32

Unclamp / Unlock All Stations

M32 Tvalue

Unclamp / Unlock ‘T” Station, where T = 1 through 19

M33

Unclamp / Lock All Stations

M34

Clamp / Unlock All Stations

M34 Tvalue

Clamp / Unlock ‘T” Station, where T = 1 through 19

M35

Clamp / Unlock All Stations Mirror

M35 Tvalue

Clamp / Unlock Mirror “T” Station, where T = 1 through 19

M36 Tvalue

Process Select “T” where T value selects the process

1 – Plasma 1

2 – Plasma 2

3 – Marker 1

4 – Marker 2

5 – Laser

M37 Tvalue (1-20)

Select Station “T” where T = 1 through 20

M38 Tvalue (1-20)

Deselect Station “T” where T = 1 through 20

M40

Start of Subroutine

M40 Xvalue

Start of Subroutine. Executes the repeat X times

M41

End of Subroutine

M48

Speed Override Enable

M49

Speed Override Disable

M50

Height Sensor Disable

M51 Txx.xx

Height Sensor Enable (Temporary Optional Time Delay in seconds
before Enable)

M52

Height Sensor Disable and Raise Torch

M53

Height Sensor Enable and Lower Torch

M63

User Defined 1 On

M64

User Defined 1 Off

M54

User Defined 2 On

M55

User Defined 2 Off

M56

User Defined 3 On

M57

User Defined 3 Off

M58

User Defined 4 Off

M59

User Defined 5 On

M65

End of Program (same as M02) or Auto Reload

M72

Marker Offset 2 Off

M73

Marker Offset 2 On

M75

A Axis/Tilt Go to Home Command - Rapid Index