Program Codes

452

G08 Xvalue

Repeat Subroutine X Times

G20

Select English Units (inches)

G21

Select Metric Units (mm)

G40

Disable Kerf Compensation

G41

Enable Left Kerf Compensation

G42

Enable Right Kerf Compensation

G43 Xvalue

Kerf Value

G41 D1-200

Enables Left Kerf using a Kerf Table variable

G42 D1-200

Enables Right Kerf using a Kerf Table variable

G43 D1-200

Sets the current Kerf value via the Kerf Table using prior set Left / Right
Kerf

G59 D1-200Xvalue Sets Kerf table variable from 1-200
G59 Vvalue Fvalue

Sets the Plasma Supply current through Outputs or Serial Link for
Vprocess (504,514,524,534) at Fcurrent value

V504 – Current Setting Plasma 1

V514 – Current Setting Plasma 2

V524 – Current Setting Marker 1

V534 – Current Setting Marker 2

G66 Dval Bval Cval Auto Align 3 Point Method with Long Offset Distance, Fast Speed, Slow

Speed values respectively

G82

Oxy-Fuel Cut Mode

G83

Oxy-Fuel Cut Mode Contour Bevel Head

G84

Plasma Cut Mode

G85

Plasma Cut Mode Contour Bevel Head

G90

Absolute Programming Mode

G91

Incremental Programming Mode

G92

Set Axis Presets

G97

Program Repeat Pointer

G97 Tvalue

Program Repeat Pointer. Executes the repeat T times

G98

Repeat at G97, or start of program if no G97

G99

Part Options


M00

Program Stop

M01

Optional Program Stop (uses Setup Parameter)

M02

End of Program

M07

Cutting Device On

M08 Txx.xx

Cutting Device Off (Temporary Optional Time Delay from –1 to 99.99
seconds)

M09

Enable Marker 1

M10

Disable Marker 1

M11

Marker Offset 1 On

M12

Marker Offset 1 Off

M13

Enable Marker 2

M14

Disable Marker 2

M15

Cut On

M16

Cut Off