Password Setups

374

This parameter is used to tell the CNC what type of control loop to run. If you are
running an external velocity loop drive (indicated by having an integrated tachometer in
the motor), select Velocity. If you are running in torque mode (no tachometer), select
Current.

DAC Polarity
This parameter allows changing of the analog output polarity to establish proper control
loop feedback without any wiring changes.

Encoder Polarity
This parameter allows changing of the encoder input polarity to establish proper counting
for positive machine motion without any wiring changes.

Encoder Decode Mode
Currently the CNC only supports 4X encoder decode mode. This has been done to
increase positional accuracy.

Follower Initially
This parameter is used to determine if the CBH axis will be On when the CNC is first
powered up.

Auto Home At Power Up
Determines if the Contour Bevel Head will automatically go into the homing routine
upon powering up the control.

Absolute Home Angle
Defines the position of the axis when the home limit switch or marker pulse is detected.

Home Offset Angle
Allows the user to set an offset angle from the home limit switch.

Use Home Limit Switch
Tells the CNC to look for a home limit switch during phase one of the homing sequence.

Home Direction
Determines which direction the axes will travel during phase one of the homing
sequence.

Use Marker Pulse
When enabled, the absolute home position will be assigned at the instant the marker pulse
is detected. It is recommended that the marker pulse be used for optimal homing
repeatability.