Voyager III

571


Status Indicator Lights
A Red and Green light are provided to indicate status of the SERCOS ring. Red indicates
a Fault and Green indicates a RUN status.

Drive Address Rotary Hex Switches
Factory settings are as follows:
For Axes 1 and 2: SW1 = 0, SW2 = 1
For Axes 3 and 4: SW1 = 0, SW2 = 3
For Axes 5 and 6: SW1 = 0, SW2 = 5
For Axes 7 and 8: SW1 = 0, SW2 = 7
For Axes 9 and 10: SW1 = 0, SW2 = 9
For Axes 11 and 12: SW1 = 0, SW2 = B

Note: Markings on backdoor machine interface for Axes are zero based.

Address Rotary Hex Switches ( for I/O only )
For I/O Expansion Interface ( no Axes being used ): SW1 = 7, SW2 = 0

Programming Port
This is for factory use only.

Dip Switch Settings

Fiber Optic Light Level:
Location SW3
Low Level (0-15 meters): 1 = OFF, 2 = OFF ( Default setting )
Medium Level (15-30 meters): 1 = OFF, 2 = ON
High Level (30-45 meters): 1 = ON, 2 = OFF
Highest Level (>45 meters): 1 = ON, 2 = ON

Baud Rate:
Location SW3
16 MBAUD 3 = ON, 4 = ON (Default setting)
8 MBAUD 3 = ON, 4 = OFF
4 MBAUD 3 = OFF, 4 = ON
2 MBAUD 3 = OFF, 4 = OFF


Reserved:
Location SW3
5 = OFF, 6 = OFF, 7 = OFF, 8 = OFF

Flash Write Jumpers:
Location SW4
1 = ON, 2 = ON