Automated Plasma Interface

502

HPR and HD4070 Part Program Support

The same Cut Chart data which is used at the Cut Chart setup screen may also be used within a part
program to configure the power supply for use. This code is used to select the set point for each
variable.

It is not necessary to have a line of code for each Cut Chart variable within a part program. Only those
variables which are changing need be inserted into the part program (e.g. Material Thickness or Material
Type).

Part program codes for the power supply

should be grouped together at the beginning of the program.

The three variables which may be set through the part program are Material Type, Current Setting and
Material Thickness.

Cut parameters for the power supply may be configured using the EIA-274D G59 code with the
following format.

Example:

G59 V503 F5

Misc. G Code
Variable Identity

V503 – Material Type Plasma 1

V513 – Material Type Plasma 2

V523 – Material Type Marker 1

V533 – Material Type Marker 2


V504 – Current Setting Plasma 1

V514 – Current Setting Plasma 2

V524 – Current Setting Marker 1

V534 – Current Setting Marker 2

V507 – Material Thickness Plasma 1

V517 – Material Thickness Plasma 2

V527 – Material Thickness Marker 1

V537 – Material Thickness Marker 2


Variable Value

V503, V513, V523, V533 – Material Type

Add

.0x for Specific Material x (for example: V503 F1 .01 for mild steel, specific material 1)

1 = Mild Steel

2 = Stainless Steel

3 = Aluminum

V504, V514, V524, 534 – Current Setting

7 = 7A

70 = 70A

10 = 10A

80 = 80A

15 = 15A

100 = 100A

18 = 18A

130 = 130A

30 = 30A

200 = 200A

45 = 45A

Advertising
This manual is related to the following products: