background image

Automated Plasma Interface

499

Outputs

Note: Similar to the standard Output Diagnostic screen, the output screen shows the current status of the
listed supply outputs. Note: Outputs for the supply cannot be activated through the diagnostic screen.

Serial Communication Interface


RS-422C Connections to HPR CNC Interface

Control (male)

Supply (male)

Signal Name

DB-9 Pin

Signal Name

DB-37 Pin

TxD- 2 RxD- 1

RxD- 3

TxD- 2

TxD+ 4 RxD+

20

RxD+ 7 TxD+

21


RS-422C Connections to HD4070 CNC Interface

Control (male)

Supply (male)

Signal Name

DB-9 Pin

Signal Name

DB-37 Pin

TxD- 2 RxD- 2

RxD- 3

TxD- 1

TxD+ 4 RxD+

21

RxD+ 7 TxD+

20