Automatic DXF Import

522

segment which is located at 350 to 10 degrees and then to the other connected segments
on the square. After the left side (vertical) segment has been cut, no additional text is
required to indicate which line should be cut. The Lead-out segment is the only segment
left to cut because the lead-in and the first segment have already been cut.

Notes:

• There should be nothing on the cut layer except lines, arcs, circles and text /

directional commands.

• Line segments must be connected to complete the cut path.
• If multiple line segments or arcs need to be repeated, each line segment should be

drawn rather than copied and pasted.

• Features for marking are not available.

• No traverse lines are required. All lines in the CAD drawing are assumed to be cut

lines.

• Left kerf is assumed.