Program Codes

480

46B

Optional Format Character Assignments

U

U U

U

VALUE

U

U U

U

U

U U

U

ASSIGNMENT

0

No Special assignment(must be used in the format location if a Delay or

Port is required but no Format options are required).
Append a Carriage Return (<CR> = Hex value OD) and a Line Feed
(<LF> = Hex Value0A)

16

Append an “Exclusive OR” (<BCC>) to the end of the message.

17

Appends a combination of 16 and 1.

32

Encloses the message with Start of Text (<STX> = Hex Value 02) and End of

Text (<ETX> = Hex Value 03). The <ETX> follows the message and the

optional <CR><LF>> append codes but precedes the Check Byte <BCC>.

33

Appends a combination of 1 and 32.

48

Appends a combination of 16 and 32.

49

Appends a combination of 1, 16 and 32.

64

Append a Start of Header (<SOH> = Hex value 01) and a End of Transmission

(<EOT> = Hex Value04) to the Message.

65

Appends a combination of 1and 64.

80

Appends a combination of 16 and 64.

81

Appends a combination of 1, 16 and 64.

96

Appends a combination of 32 and 64.

97

Appends a combination of 1, 32, and 64.

112

Appends a combination of 16, 32 and 64.

113

Appends a combination of 1, 16, 32 and 64.

47B

Optional Delay Time/Time Out Value

The Delay Value will issue a delay in seconds at the end of the message for Message Type 20.

No delay is supported for Message Type 21.

This value also works as a Time Out value for Message Type 22. An error will be displayed if
the message is not acknowledged (ACK Hexadecimal 06) within the specified time. If no
Time Out Delay is defined in the command, the Time Out parameter on the Ports screen will be
used.

The value is in a 3.2 format where a value of 5 is equal to 5.00 seconds. Accepted limits for the
value is range of 0.00 to 999.99 seconds.

If there is no delay, but the optional port below is being selected, then 0 is required to be
entered in the optional delay location.

48B

Optional Port

The Optional Port setting selects which Messaging Port to use. The default messaging port to
use is Port 1 if this parameter is omitted. If the optional port is used, 0 = Messaging Port 1 and
1 = Messaging Port 2.