Password Setups

357

Slow Home Speed until the switch is deactivated. See also Tilt
Overtravel Switch.


Rotate +/–

Used for manual jog commands for the rotate axis.


Rotate Home Switch

Indicates that the machine has traveled to its rotate axis home
position. When the rotate axis is homed, it moves in the
specified home direction at the Fast Home Speed until the
input is activated. The rotate axis decelerates to a stop, moves
in the opposite direction at the Slow Home Speed until the
switch is deactivated.


Pierce Complete

Used for the laser cut process to confirm that the pierce is
complete.


Gas Control Read Comp. Used as part of the HD3070 Automatic Gas Console

communication to confirm that communication is complete.


Gas Control Error

Used as part of the HD3070 Automatic Gas Console
communications to indicate an error from the Auto Gas
Console.


Enable Oxy Fuel 1-12

Used for tracking consumable data for the specified oxy torch.
This input is now supported by the Station Select input.


Enable Plasma 1-8

Used for tracking consumable data for the specified plasma
torch. This input is supported by the Station Select input.


Arc Error Counter 1-8

Used as part of consumable data tracking, this input triggers a
counter on the Change Consumable Screen. A Plasma Enable
Input must be mapped to enable this input.


Test Lifter

Performs a test IHS function with a Sensor THC.

Output Logic
The CNC comes standard with up to 32 discrete outputs. The Output Logic parameter is
used as a mask to determine whether or not the output is to be treated as a normally open
contact or as a normally closed contact.

Logic Selection Box
The Logic Selection Box allows the user to select the Logic state for each input to be
either normally open or normally closed. The logic state for the inputs can be switched by
selecting the desired Output and pressing the space key.

Output Selection
The Output Selection box feature is used to define which inputs will be used by the
control, and their physical location on the control interface. All controls are shipped with