5.4.3.3 General Parameters
5.4.3.3.1 Query General Parameters
The message format is:
QG<Command ID>
Command ID = <Byte> (See
.)
Command Response:
ACK<Integer> (All the QG responses are integers.)|<Response Error Code>
Special Case: QG0 will return all General Parameters, in numeric order.
5.4.3.3.2 Update General Parameters
Update: The message format is:
UG<Command ID><Parameter Value>
Command ID = <byte> See "Command ID" column in table below.
Parameter Value = <integer>
Description: type of parameter value depends on Command ID, see
"units" column of
Command Response:
ACK|<Response Error Code>
NOTE: General parameters may only be updated if all channels are in Ready or
Stop and are not crystal switching on any channel.
Special Case: UG0 will send all General parameters in numeric order.
Table 5-5 General Parameters
QG
Command
ID
Name
Units / Allowed
Values / Notes
Low Limit
High Limit
1
(0x01)
Test On
1 = Yes, 0 = No
0
1
2
(0x02)
Time
Compressed
1 = Yes, 0 = No
0
1
3
(0x03)
Audio
Feedback
1 = Yes, 0 = No
0
1
4
(0x04)
(Not Used)
Int
0
0