1 - 14

IP

N 07

4-

37

9-

P1

K

Cygnus Operating Manual

1.4.6 Logic Processing

Type . . . . . . . . . . . . . . . . . . . . . . . . . If/Then statements

Logical Functions . . . . . . . . . . . . . . . And; Or; Not; Parentheses

Depth . . . . . . . . . . . . . . . . . . . . . . . . 5 "If" conditions and 5 "Then" results/actions

per statement

# of Statements . . . . . . . . . . . . . . . . 100 If/Then

Selectable events . . . . . . . . . . . . . . . Deposition monitor events, states, external

inputs, relays, timers, and counters.

Hierarchy . . . . . . . . . . . . . . . . . . . . . Statements evaluated in numerical order at

10 Hz any time the unit is on.

Partitioning . . . . . . . . . . . . . . . . . . . . None

Initialization . . . . . . . . . . . . . . . . . . . All outputs transition to their normal states as

early as possible during power-on
initialization sequence.

1.4.7 Relays / Inputs

Relays . . . . . . . . . . . . . . . . . . . . . . . SPST 2.5 A relays rated @ 30 V(dc) or

30 V(ac) RMS or 42 V(peak) maximum;
(8 standard, up to 16 optional with 2
additional I/O cards); D sub connector; relays
are normally open in the power off state, but
may be programmed to normally open or
normally closed during operation.

Relay Ratings. . . . . . . . . . . . . . . . . . 100 VA inductive; 2.5A maximum.

# of TTL Compatible Outputs . . . . . . 14 with optional I/O card. Internally pulled up

to 5 V(dc). May be pulled up externally to
24 V(dc) through 2.4k resistor.
minimum high level 0.5mA load @3.75 V
maximum low level 10mA load @1.1 V

Inputs (TTL Compatible). . . . . . . . . . (14 standard, 14 additional optional)

Input Levels

maximum high . . . . . . . . . . . . . . 24 V

minimum high . . . . . . . . . . . . . . . 2.5 V

maximum low . . . . . . . . . . . . . . . 1.1 V

Scan/Update Rate . . . . . . . . . . . . . . 10 Hz

Advertising