◦ Usual values are: /dev/ttyS0 for embedded serial port on the motherboard and

/dev/ttyUSB0 for any USB-serial converter.

Speed, Data, Stop Bits, Parity and Flow control are usual parameters used to configure

serial communication. Refer to the original automation documentation to find out what
the correct values are. Usual value is 115200 8N1. No flow control.

Figure 136: Device Manager GUI - Serial Device Added

Message type: This parameter indicates how incoming text will be parsed to build

messages. In order to match most existing protocol, two different incoming message
types are handled (Figure 137).

◦ Fixed-length messages: All messages are always expected to be the same length.

The user has to provide the message length parameter.

◦ End of Line Byte message: All messages are expected to have a special "magic"

character to indicate the end of message. This type matches most text-based
protocol with an end of line character (\n) to validate the entry. The user has to
provide the end of message "magic" character. Multiple character sequence is not
supported (e.g., \r\n). Note that the "magic" character will NOT be part of the
message sent to the playback engine.

Save the new configuration by clicking the Save button.