Clear. Clicking this button clears the data points displayed in the graphs.

Time in Graph. This setting selects the total time that data points are accumulated on the graph. When a
different time setting is selected, the x-axis grid numbers automatically adjust to maintain 16.667
milliseconds between points. A time setting of 200 ms, 516 ms, 1.03 s, 2.08 s, 4.16 s, 8.33 s, 16.67 s, or
33.33 s may be selected.

Scroll Graph. Clicking this button displays the X Axis Start Point setting box which displays the
permissible range for the x-axis start point and accepts a number representing a starting point for scrolling
across the x-axis.

Maximize/Restore. This button expands the Analysis screen to a full-screen size and restores the
Analysis screen to its normal, default size.

Exit. Clicking this button exits the Analysis screen and returns to the last-viewed screen.

Graph Settings

Parameter. This setting selects the parameter to be displayed on the graph. Any one of the following
parameters may be selected:

•

Aux voltage input (Vaux)

•

Average line current (Iavg)

•

Average line-to-line voltage (Vavg)

•

AVR error signal (Errln)

•

Bus frequency (BHz)

•

Bus voltage (Vbus)

•

Compensated frequency deviation (CompF)

•

Control output (CntOp)

•

Cross-current input (Iaux)

•

Field current (Ifd)

•

Field voltage (Vfd)

•

Field temperature

•

Filtered mechanical power (MechP)

•

Final PSS output (Pout)

•

Freq response signal (Test)

•

Generator frequency (GHz)

•

Ia phase angle (PhA)

•

Iaux phase angle (PhAux)

•

Ib phase angle (PhB)

•

Ic phase angle (PhC)

•

Internal state (TrnOp)

•

Lead-lag #1 (x15)

•

Lead-lag #2 (x16)

•

Lead-lag #3 (x17)

•

Lead-lag #4 (x31)

•

Mechanical power (x7)

•

Mechanical power LP #1 (x8)

•

Mechanical power LP #2 (x9)

•

Mechanical power LP #3 (x10)

•

Mechanical power LP #4 (x11)

•

Negative sequence current (I2)

•

Negative sequence voltage (V2)

•

Null balance (%)

•

OEL controller output (OelOutput)

•

PF mode output (VPfOp)

•

Phase A current (Ia)

•

Phase A to B, line-to-line voltage (Vab)

•

Phase B current (Ib)

•

Phase B to C, line-to-line voltage (Vbc)

•

Phase C current (Ic)

•

Phase C to A, line-to-line voltage (Vca)

•

Position indication (%)

•

Positive sequence current (I1)

•

Positive sequence voltage (V1)

•

Post-limit output (Post)

•

Power factor (PF)

•

Power HP #1 (x5)

•

Pre-limit output (Prelm)

•

PSS electrical power (Pss/kW)

•

PSS term voltage (Vtmag)

•

Rate of frequency change

•

Reactive power (kvar)

•

Real power (kW)

•

SCL controller output (SelOutput)

•

Speed HP #1 (x2)

•

Synthesized speed (Synth)

•

Terminal frequency deviation (TermF)

•

Time response signal (PTest)

•

Torsional filter #1 (Tflt1)

•

Torsional filter #2 (x29)

•

Total power (kVA)

•

UEL controller output (UelOutput)

•

Vab phase angle (PhAB)

•

VARL controller output (PU)

•

Vbc phase angle (PhBC)

•

Washed out power (WashP)

•

Washed out speed (WashW)

Y-Axis Max. This setting selects the maximum value of the y axis.

Y-Axis Min. This setting selects the minimum value of the y axis.

Filter (Hertz). This setting selects the cutoff filter frequency for the parameter to be graphed.