Basler Electric DECS-400 User Manual

Page 234

Advertising
background image

222

9369700990 Rev R

Registers

Data Description

Access

Data

Format

41443 to
41469

Reserved for future C7 use

RW

Not

Defined

41471

Active SCL Limiter Setting Group

R

UINT16

41472 to
41480

Not used

R

Not

Defined

41481

Primary SCL High Current Level

RW

FLOAT

41483

Primary SCL High Current Time

RW

FLOAT

41485

Primary SCL Medium Current Level

RW

FLOAT

41487

Primary SCL Medium Current Time

RW

FLOAT

41489

Primary SCL Low Current Level

RW

FLOAT

41491

Primary SCL No Respoonse Time

RW

FLOAT

41493 to
41584

Reserved for future C7 use

R

Not

Defined

41585

OEL dv/dt Setting

RW

FLOAT

41587

Var limiter setpoint for primary selection

RW

FLOAT

41589

Var limiter initial delay for primary selection

RW

FLOAT

41590 to
41720

Reserved for future C7 use

R

Not

Defined

41721

Secondary On-Line OEL Setting - High Current Level

RW

FLOAT

41723

Secondary On-Line OEL Setting - High Current Time

RW

FLOAT

41725

Secondary On-Line OEL Setting - Medium Current Level

RW

FLOAT

41727

Secondary On-Line OEL Setting - Medium Current Time

RW

FLOAT

41729

Secondary On-Line OEL Setting - Low Current Level

RW

FLOAT

41731

Secondary Off-Line OEL Setting High Current Level

RW

FLOAT

41733

Secondary Off-Line OEL Setting Low Current Level

RW

FLOAT

41735

Secondary Off-Line OEL Setting High Current Time

RW

FLOAT

41737

Secondary Takeover Off-Line OEL High Current Level

RW

FLOAT

41739

Secondary Takeover Off-Line OEL Low Current Level

RW

FLOAT

41741

Secondary Takeover Off-Line OEL Time Dial

RW

FLOAT

41743

Secondary Takeover On-Line OEL High Current Level

RW

FLOAT

41745

Secondary Takeover On-Line OEL Low Current Level

RW

FLOAT

41747

Secondary Takeover On-Line OEL Time Dial

RW

FLOAT

41749 to
41780

Reserved for future C7 use

R

Not

Defined

41781

Secondary UEL Curve Real Power 1st Point

RW

FLOAT

41783

Secondary UEL Curve Real Power 2nd Point

RW

FLOAT

41785

Secondary UEL Curve Real Power 3rd Point

RW

FLOAT

41787

Secondary UEL Curve Real Power 4th Point

RW

FLOAT

41789

Secondary UEL Curve Real Power 5th Point

RW

FLOAT

41791

Secondary UEL Curve Reactive Power 1st Point

RW

FLOAT

41793

Secondary UEL Curve Reactive Power 2nd Point

RW

FLOAT

41795

Secondary UEL Curve Reactive Power 3rd Point

RW

FLOAT

41797

Secondary UEL Curve Reactive Power 4th Point

RW

FLOAT

41799

Secondary UEL Curve Reactive Power 5th Point

RW

FLOAT

41801

Secondary UEL Bias

RW

FLOAT

41803 to
41840

Reserved for future C7 use

R

Not

Defined

41841

Secondary SCL High Current Level

RW

FLOAT

41843

Secondary SCL High Current Time

RW

FLOAT

41845

Secondary SCL Medium Current Level

RW

FLOAT

41847

Secondary SCL Medium Current Time

RW

FLOAT

41849

Secondary SCL Low Current Level

RW

FLOAT

41851

Secondary SCL No Respoonse Time

RW

FLOAT

41853

Var limiter setpoint for secondary selection

RW

FLOAT

Modbus™ Communication

DECS-400

Advertising