Operation example (logic 11d) – IDEC FS1A Controller User Manual

Page 102

Advertising
background image

LOGIC

5-54

Logic 11d: Muting function logic for apparatus with openings

Overview (Logic 11d)

The logic is for using safety devices with dual channel solid state outputs, such as safety light
curtains, and for devices with output muting signals that enable muting functions that temporarily
suspend safety functions of safety devices for safety protective measures of robots and conveyor
lines.

Safety outputs perform as dual channel outputs.

This logic enables the connection of 2 dual channel direct opening inputs and 2 dual channel safety
inputs and 2 muting signal output (PNP) devices (Ex. Muting sensor, limit switch).

(※)

Hazardous Area

Work object

Safety light
curtain

(※)

System runs

Muting sensors

Muting lamp

Make sure that the
intersection of optical
axes is within the
hazardous areas.

PNP type)

(PNP type)

Safety light
curtain

Emergency
stop switch

Logic 11d

Safety
output 1

Safety
output 2

Muting sensor

Muting lamp

Operation example (Logic 11d)

● Safety input is temporarily suspended

Safety light curtain beams blocked

Muting sensor beams blocked

Muting lamp

System runs

Safety light curtain beams blocked

Hazardous Area

● Safety light curtain beams blocked

System stops

Safety light curtain beams blocked

Hazardous Area

Warning

When installing light curtains and muting sensors, ensure safety by referring to referring to IEC TS
62046 technical documents..