Wiring example (logic 11a), Logic – IDEC FS1A Controller User Manual

Page 74

Advertising
background image

LOGIC

5-26

Wiring example (Logic 11A)

In the case where 4 safety light curtains, 1 emergency stop switch, and 1 interlock switch with solenoid (spring
lock type) are connected.


S1 to 4 :Safety light curtain
S5

:Emergency stop switch

S6

:Interlock switch with solenoid (spring lock type)

S7 :Start

switch

S8

:Solenoid control switch

(Pressing the solenoid control switches after closing the guard door,
contacts 41-42 and 51-52 of S6 turn on, allowing the SafetyOne to restart.)
K1 to 4 :Contactor
M1, 2

:Motor

V+

X0

X1

T0

T1

24V DC

X6

X7

T6

T7

X10

T10

X11

T11

X12

T12

X13

T13

X14

T14

X15

T15

K1

K2

K3

K4

X16

S7

X17

S1

24V

0V

OSSD1

OSSD2

K1

V-

Y4
Y5
Y6
Y7

Y10
Y11
Y12
Y13
Y14
Y15

Y17

Y20

Y0

Y16

K2

Y1

K3

Y2

K4

Y3

To
PLC

SafetyOne

FE

S4

24V

0V

OSSD1

OSSD2

X2

X3

T2

T3

S2

24V

0V

OSSD1

OSSD2

X5

T5

X4

T4

S3

24V

0V

OSSD1

OSSD2

S5

Guard open

11

12

51

52

42

A1(-)

A2(+

)

41

S6

21

22

S8

Actuator

Interlock switch with solenoid
(spring lock type)

0V DC

Fuse

When not using some inputs

K2

K1

M1

K4

K3

M2

Advertising