Logic circuit (logic 11d), 2k+1, Logic – IDEC FS1A Controller User Manual

Page 103: Monitor output for muting input

Advertising
background image

LOGIC

5-55

Chapter 5

Logic circuit (Logic 11d)

X0, X1

X2, X3

X4, X5

X6, X7

T12, X12, T13, X13

T10, X10, T11, X11

T14, X14

T15, X15

X16

X17

Safety input 1

Safety input 4

Safety input 3

Muting input 2

Safety input 2

Muting input 1

Start input 1

Start input 2

External device
monitor 2

External device
monitor 1

Muting

Muting

Y0

Y1

Y2
Y3

Safety output 1

&

=2k+1

Control

Contorl

Start

Hold

EDM

OSSD

Muting

function

Safety

input

Muting

( ∞ )

OS1

Dual Channel Safety

Dual Channel Safety

Hold

EDM

OSSD

with

Off delay

External Device

Monitor

EDM

External Device

Monitor

EDM

Single Channel

Monitor

Single Channel

Monitor

Dual Channel

Direct Opening

Dual Channel

Direct Opening

Hold

Trigger

Self-hold

function

Self-hold

function circuit 1

Muting

function

Safety

input

Muting

( ∞ )

OS1

Y12

Y13

X1

X0

Y4

X3

X2

Y5

X5

X4

Y6

X7

X6

Y7

X11

X10

Y10

X13

X12

Y11

Monitor output for safety input

Monitor output for safety output

Muting lamp output

X3

X2

Y17

X7

X6

Y20

Y0,Y1

Y2,Y3

Safety input 1
monitor

Muting input 1
monitor

Safety input 2
monitor

Muting input 2
monitor

Safety input 3
monitor

Safety input 4
monitor

Safety output 1
monitor

Safety output 2
monitor

(Note1)

Monitor output for muting input

&

&

&

&

&

&

&

&

&

Note1:
Safety output 2 monitor turns OFF
immediately independent of OFF-delay
time.

(Note2)

Note2:
The muting lamp output turns ON when
the safety function of the safety input is
temporarily suspended.
Even if the muting input is ON when the
safety output is OFF, the muting lamp
output doesn't turn ON.
In case of the SafetyOne is turned ON
when the muting input is ON or the
safety output turns OFF when the
muting input is ON, muting function is
not activated without turning off of muting
input.

Muting lamp output 2

Muting lamp output 1

(Note2)

Advertising