Timing chart (logic 13d), Logic, Example: teach 1 – IDEC FS1A Controller User Manual

Page 243

Advertising
background image

LOGIC

5-195

Chapter 5

Timing chart (Logic 13d)

Example: TEACH 1

Max. 6s

Initialization

Monitor output for
Safety output 1: Y12

State monitor output 3:
Y16

Safety input 1: X0
(Mode select input:
Teach 1)

Safety input 2: X2
(Mode select input:
Teach mode)

Monitor output for
safety input 2: Y5

Monitor output for safety
input 1: Y4

Monitor output for
safety input 3: Y6

Safety input 1: X1
(Mode select input:
Teach 2)

Safety input 3: X4

Start input 2: X17
(Control)

Safety input 2: X3
(Mode select input:
Auto mode)

Max. 0.1s

Safety output 1:
Y0, Y1

note 2)

Safety output 2:
Y2, Y3

Monitor output for
Safety output 2: Y13

Monitor output for
Teach 1: Y17

Start input 1: X16
(Manual)

Min. 0.1s

Safety input 3: X5

note 2)

Monitor output for
safety input 6: Y11

Safety input 6: X12,
X13

Max. 0.1s

Monitor output for
Teach 2: Y20

Monitor output for
safety input 4: Y7

Safety input 4: X6,
X7

Monitor output for
safety input 5: Y10

Safety input 5: X10,
X11

Max. 3s

note 1)

0.1s to 5s

OFF delay time

OFF delay time

Safety

output

ON

Power

ON

Safety

output

ON

Safety

output

ON

Switch to

Teach 2

Note 1) When “Safety input 1 (mode select input)” is switched to another mode within 3s, all of “Safety output” are

kept ON.

Note 2) Input monitor error detection time is infinity.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel dependent input (X6, X7) is infinity.

The time of dual channel safety input (X10, X11) is 0.1s.

The time of dual channel direct opening input (X12, X13) is 0.5s.

Refer to the following “Logic functions” for more details.