IDEC FS1A Controller User Manual

Page 26

Advertising
background image

PRODUCT SPECIFICATIONS

2-14


(3) Timer LED

Indication

Status

Descriptions

0

ON

No OFF-delay (safety outputs shut off immediately)

.1

ON

OFF-delay timer 0.1s

.5

ON

OFF-delay timer 0.5s

1

ON

OFF-delay timer 1s

2

ON

OFF-delay timer 2s

5

ON

OFF-delay timer 5s

15

ON

OFF-delay timer 15s

30

ON

OFF-delay timer 30s

Each LED

Blink

Selected timer value (Configuration state)

Random

ON/Blink

Initializing (Initial state)

Blank

OFF

Timer value is not selected or SafetyOne is in the Stop
state

(4) Input LED: SAFE-IN (X0 … X15), START-IN (X16, X17)

Indication

Status

Descriptions

ON

Input ON

OFF

Input OFF, or SafetyOne is in the Stop or Configuration
state

X0 to X15

Blink

Input monitor error
(Blink input number the error occurred, error number is
displayed at Error LED)

ON

Input ON

OFF

Input OFF, or SafetyOne is in the Stop or Configuration
state

X16, X17

Blink

Input monitor error
(Blink input number the error occurred, error number is
displayed at Error LED)

Indicators specification of input LEDs are different depending on the selected logic.

(5) Output LED: SAFE-OUT (Y0 … Y3), SOLENOID-OUT (Y17, Y20)

Indication

Status

Descriptions

ON

Output ON

OFF

Output OFF, or SafetyOne is in the Stop or Configuration
state

Y0 to Y3

Blink

During OFF-delay timer operation, or output monitor error
(Blink output number the error occurred, error number is
displayed in Error LED display)

ON

Output ON

OFF

Output OFF, or SafetyOne is in the Stop or Configuration
state

Y17, Y20

Blink

Output monitor error
(Blink output number the error occurred, error number is
displayed in Error LED display)

Advertising