Operation example (logic 12c), Logic, Logic 12c – IDEC FS1A Controller User Manual

Page 154

Advertising
background image

LOGIC

5-106

Logic 12C: The logic constructing an OR circuit for apparatus with openings

Overview (Logic 12C)

This logic is for constructing an OR circuit of safety devices with dual channel solid state outputs,
such as safety light curtains, for safety protective measures of production machinery, robots. Safety
outputs perform as dual channel outputs.
This logic enables the connection of 4 dual channel direct opening inputs, and 2 dual channel safety
inputs.

Workspace

Safety input 1

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

System runs

Emergency
stop switch

Safety switch

Limit switch

Safety light
curtain

(PNP type)

Logic 12C

Safety
output 1

Safety
output 2

Operation example (Logic 12C)

Beams
blocked!

Safety input 1

Safety input 6

Safety output 1
or
Safety output 2

Safety input 4

Safety input 2

Safety input 3

Safety input 5

System runs

Workspace

Safety input 1

Safety input 6

Safety output 1
or
Safety output 2

System runs

Safety input 3

Safety input 4

Workspace

Beams
blocked!

Safety input 2

Safety input 5

Safety input 1

Safety input 6

Safety output 1
or
Safety output 2

Safety input 3

Safety input 5

Safety input 2

Safety input 4

Beams
blocked!

Beams
blocked!

Workspace

System stops