LOGIC

5-73

Chapter 5

●Safety outputs: Y0 to Y3

Safety outputs are used to output safety information processed by SafetyOne.

Intended outputs
(Terminal names)

Function

Function name

Safety output with timer

Symbol

Hold

EDM

OSSD

with

Off delay

Description of operation

This function is a safety output to output safety
information processed by SafetyOne. The
output is turned OFF after the preset time of the
OFF-delay timer (OFF-delay output).

Safety output 1
(Y0, Y1)
Safety output 2
(Y2, Y3)

Detail information

Logic functions (5-335)

Note. When the SafetyOne changes to Protection state due to input monitor error, all safety outputs

(safety output 1 and safety output 2) are turned OFF after the preset OFF-delay time.

Note. When the SafetyOne changes to Stop state due to circuit failure or other errors, all safety

outputs (safety output 1 and safety output 2) are turned OFF, immediately.