Chapter 5

Timing chart (Logic 14d)

Example: Teach mode

Safety input 1: X0
(Mode select input :
Teach mode

)

Safety input 2: X2

Monitor output for
safety input 2: Y5

Monitor output for
safety input 1: Y4

Start input 1: X16
(Manual)

Safety input 1: X1
(Mode select input:
Auto mode)

Max. 6s

Initialization

State monitor output 3:
Y16

Safety input 2: X3

note 1)

note 1)

Safety output 1: Y0

Min. 0.1s

Start input 2: X17
(Control)

Monitor output for
Safety output 1: Y12

Safety output 2: Y1

Monitor output for
Safety output 2: Y13

Safety output 3-1:
Y2

Monitor output for
Safety output 3-2: Y20

Monitor output for
safety input 5: Y10

Safety input 5:
X10, X11

0.1s to 5s

Monitor output for
Safety output 3-1: Y17

Safety output 3-2: Y3

Monitor output for
safety input 4: Y7

Safety input 4: X6,
X7

Safety input 3: X4, X5

Monitor output for
safety input 3: Y6

Max. 0.1s

OFF delay time

OFF delay time

Max. 0.1s

OFF delay time

OFF delay time

Power

ON

Safety
output

2, 3

ON

Switch to

Auto

mode

Safety

output

2, 3

ON

Safety

output

2, 3

ON

Safety
output

2, 3

ON

Safety
output

1 to 3

ON

OFF delay time

OFF delay time

OFF delay time

Note 1) Input monitor error detection time is infinity.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel direct opening input (X4 to X7) is 0.5s.

The time of dual channel safety input (X10, X11) is 0.1s.

Refer to the following “Logic functions” for more details.