LOGIC

5-142

Timing chart (Logic 103)

Example: Teach mode

Max. 0.1s

Monitor output for
safety input 4: Y7

Safety input 4: X6,
X7

Safety output 2:
Y2, Y3

Safety input 1: X0
(Mode select input:
Teach mode)

Safety input 2: X2

Monitor output for
safety input 2: Y5

Monitor output for
safety input 1: Y4

Monitor output for
safety input 6: Y11

Start input 1: X16
(Manual)

Safety input 1: X1
(Mode select input:
Auto mode)

Max. 6s

Initialization

Monitor output for
Safety output 1: Y12

Solenoid output 2:
Y20

State monitor output 3:
Y16

Safety input 6: X12,
X13

Start input 2: X17
(Control)

Safety input 2: X3

note 2)

note 2)

Safety output 1:
Y0, Y1

Min. 0.1s

Monitor output for
Safety output 2: Y13

Solenoid output 1:
Y17

Max. 0.1s

Switch

to auto

mode

Max. 3s

note 1)

Min. 0.1s

Power

ON

Safety
output

2

ON

Safety
output

1

ON

OFF delay time

OFF delay time

OFF delay time

Safety
output

1

ON

Safety

output

1, 2

ON

(Both safety input 3 and 5 are ON in this chart.)

Note 1) When “Safety input 1(mode select input)” is switched to another mode within 3s, “Safety output 1” is kept

ON. ”Safety output 2" is unrelated to mode select input.

Note 2) Input monitor error detection time is infinity.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel dependent input (X4, X5, X12 and X13) is infinity.

The time of dual channel direct opening input (X6, X7) is 0.5s.

The time of dual channel safety input (X10, X11) is 0.1s.

Refer to the following “Logic functions” for more details.