LOGIC

5-92

Logic 12b: The logic constructing an OR circuit for various apparatus

Overview (Logic 12b)

This logic is for constructing an OR circuit of a safety input device for safety protective measures of
production machinery, robots.. Safety outputs perform as dual channel outputs.
This logic enables the connection of 4 dual channel direct opening inputs, and 2 dual channel
dependent inputs.

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

Safety input 1

System runs

Safety
output 1

Safety
output 2

Logic 12b

Emergency
stop switch

Safety switch

Enabling

switch

Operation example (Logic 12b)

System stops

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

Safety input 1

Open!

Position1!
Position3!

Position 2!

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

Safety input 1

System runs

Open!

Open!

Press!

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

Safety input 1

System stops