Timing chart (logic 14b), Logic, Example: teach mode – IDEC FS1A Controller User Manual

Page 280

Advertising
background image

LOGIC

5-232

Timing chart (Logic 14b)

Example: Teach mode

Safety input 1: X0
(Mode select input :
Teach mode

)

Safety input 2: X2

Monitor output for
safety input 2: Y5

Monitor output for
safety input 1: Y4

Start input 1: X16
(Manual)

Safety input 1: X1
(Mode select input:
Auto mode)

Max. 6s

Initialization

State monitor output 3:
Y16

Safety input 2: X3

note 2)

note 2)

Safety output 1-1:
Y0

Start input 2: X17
(Control)

Monitor output for Safety
output 1-1: Y12

Safety output 1-2: Y1

Monitor output for Safety
output 1-2: Y13

Safety output 2: Y2

Monitor output for
Safety output 3: Y20

Safety input 3: X4,
X5

Monitor output for
safety input 5: Y10

Safety input 5: X10,
X11

0.1s to 5s

Monitor output for Safety
output 2: Y17

Safety output 3: Y3

Max. 0.1s

note 1)

Monitor output for
safety input 3: Y6

Max. 0.1s

Min. 0.1s

OFF delay time

OFF delay time

OFF delay time

Safety

output 1

ON

Power

ON

Switch

to Auto

mode

Safety

output 3

ON

Safety

output 1

ON

Safety

output

1, 3
ON

Safety

output

1, 2

ON

Max. 3s

(Safety input 4 is ON in this chart.)

Note 1) When Safety input 1 (mode select input) is switched to Auto mode from Teach mode, Safety output 1 is kept

ON for 3s maximum till X1 is turned ON after X0 is turned OFF. Safety output 1 is turned OFF at the same
time as X1 is turned ON. Safety output 3 is unrelated to mode select input.

Note 2) Input monitor error detection time is infinity.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.
The time of dual channel direct opening input (X4 to X11) is 0.5s.
Refer to the following "Logic functions" for more details.