LOGIC

5-78

Timing chart (Logic 102)

Example: Manual start input (X16) is used.

OFF delay time

OFF delay time

Safety input 1: X0

Start input 1: X16
(Manual)

Safety output 1: Y0,
Y1

Monitor output for
safety input 1: Y4

Monitor output for
Safety output 1: Y12

State monitor output 3:
Y16

Solenoid output 2:
Y20

Safety input 1: X1

Min. 0.1s

Max. 6s

Initialization

note 1)

Max. 0.1s

note 1)

Safety input 4: X6,
X7

Monitor output for
safety input 4: Y7

Safety output 2:
Y2, Y3

Monitor output for
Safety output 2: Y13

Solenoid output 1:
Y17

Power

ON

Safety

output

ON

Safety

output

ON

(Safety input 2, 3, 5 and 6 are all ON in this chart.)

Note 1) Input monitor error detection time is 0.5s.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel direct opening input (X2 to X5) is 0.5s.

The time of dual channel safety input (X6 to X13) is 0.1s.

Refer to the following “Logic functions” for more details.