Timing chart (logic 12c) – IDEC FS1A Controller User Manual

Page 165

Advertising
background image

LOGIC

5-117

Chapter 5

Timing chart (Logic 12C)

Example: Manual start input (X16) is used.

Min. 0.1s

Max. 0.1s

Safety input 1: X0

Start input 1: X16
(Manual)

Monitor output for
safety input 1: Y4

State monitor output 3:
Y16

Solenoid output 1:
Y17

Safety input 1: X1

Max. 6s

Initialization

Safety input 2:
X2, X3

Safety output 1:
Y0, Y1

Monitor output for Safety
output 1: Y12

Safety output 2:
Y2, Y3

Monitor output for Safety
output 2: Y13

Solenoid output 2:
Y20

Monitor output for
safety input 2: Y5

Safety input 3:
X4, X5

Monitor output for
safety input 3: Y6

note 1)

note 1)

Power

ON

Safety

output

ON

Safety
output

ON

Safety
output

ON

OFF delay time

OFF delay time

(Safety input 4, 5 and 6 are all ON in this chart.)

Note 1) Input monitor error detection time is 0.5s.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel direct opening input (X4, X5 and X10 to X13) is 0.5s.

The time of dual channel safety input (X2, X3, X6 and X7) is 0.1s.

Refer to the following “Logic functions” for more details.