Logic 11a:the logic for apparatus with openings, Operation example (logic 11a) – IDEC FS1A Controller User Manual

Page 66

Advertising
background image

LOGIC

5-18

Logic 11A: The logic for apparatus with openings

Overview (Logic 11A)

This logic is for using safety devices with dual channel solid state outputs, such as safety light
curtains, for safety protective measures of production machinery and robots. Safety outputs perform
as dual channel outputs.
This logic enables the connection of 2 dual channel direct opening inputs and 4 dual channel safety
inputs.

Safety input 1

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

System runs

Safety
output 1

Safety
output 2

Logic 11A

Emergency
stop switch

Safety light
curtain
(PNP type)

Safety switch

Operation example (Logic 11A)

System stops

Beams
blocked!

Safety input 1

Safety input 5

Safety input 6

Safety input 4

Safety input 3

Safety input 2

Safety output 1
or
Safety output 2

Press!