LOGIC

5-64

When not using the start switch

Auto start

When not detecting the welding of start switch

Manual start

When detecting the welding of start switch

Control start

When connecting multiple components in series

NOTE: Safety performance depends
on the system configuration.

When not using some safety inputs

Note: In Logic 11d,the muting lamp output terminals
(Y17 and Y20) detect that connected indicator lights are
disconnected or unconnected.
When not using the muting function,
connect a resistor across these terminals.
If no resistor is connected, then the SafetyOne
detects any wiring errors and locks out operations.

If there are unused safety inputs in S1 and S4, connect the

unused receive terminals to 24V DC power supply (V+).
(Refer to (1))

If there are unused muting inputs in S2,S3, S5 and S6,

open between the unused receive terminals and the
orresponding drive terminals . (Refer to (2))
・If there are unused safety inputs in S7 and S8,
connect the unused recieve terminals to the corresponding
drive terminals. (Refer to (3))