Two hand control, Description of operation – IDEC FS1A Controller User Manual

Page 379

Advertising
background image

LOGIC

5-331

Chapter 5

Two hand control

This function adds a two hand control function to the connected the safety device. As shown in
Fig.5-30, this function is comprised of 2 safety inputs (I

n

, I

n+1

) and a functional output (O

n

). The

function outputs of dual channel NO/NC output are connected to safety inputs (I

n

, I

n+1

) of this

function.



Fig. 5-30 Two hand control function circuit

Description of operation

The operation timing is described in Fig. 5-31.

I If the both of safety inputs turn ON, function output turns ON.
II If the one of safety outputs turns, function output turns OFF.

(1) The input status of both of safety inputs are different over the input monitoring error detection

time (0.5s), function output kept at OFF state.

(2) The one of inputs change the state independently on another input, function output kept at

OFF state.

Input monitor error
detection time:Max.0.5s

Over 0.5s

② Independent conditon

change in one input

I

n

I

n+1

O

n

ON

OFF

ON

OFF

ON

OFF

Fig. 5-31 Operation timing of the two hand control function





I

n

O

Two-hand

control

Type IIIC

Safety Input 1

Safety Input 2

I

n+1

Advertising