Wiring example (Logic 13C)

In the case where 1 selector switch, 1 enabling swithc, 2 interlock switch with solenoid (spring lock type), 1
emergency stop switch, and 1 safety light curtain are connected.


S1 :Selector

switch

S2 :Enabling

switch

S3, 4

:Interlock switch with solenoid (spring lock type)

S5

:Emergency stop switch

S6 :Safety

light

curtain

S7, 8

:Start switch

S9, 10

:Solenoid control switch

(Pressing the solenoid control switches after closing the guard door,
contacts 41-42 and 51-52 of S3 and S4 turn on, allowing the SafetyOne to restart.)
K1 to 4 :Contactor
M1, 2

:Motor

V+

X0

X1

T0

T1

24V DC

0V DC

X13

T13

X15

T15

X16
X17

K1

V-

Y4
Y5
Y6
Y7

Y10
Y11
Y12
Y13
Y14
Y15

Y17

Y20

Y0

Y16

K2

Y1

K3

Y2

K4

Y3

To
PLC

SafetyOne

FE

S1

X2

X3

T2

T3

S2

X6

X7

T6

T7

X5

T5

T4
X4

X10

T10

X11

T11

X12

T12

X14

T14

S5

S7

S8

S6

24V

0V

OSSD1

OSSD2

Guard open

11

12

51

52

42

A1(-)

A2(+

)

41

S3

21

22

S9

S10

Guard open

11

12

51

52

42

A1(-)

A2(+

)

41

S4

21

22

Interlock switch with solenoid
(spring lock type)

Interlock switch with solenoid
(spring lock type)

Actuator

Actuator

K1

K2

K3

K4

Fuse

K2

K1

M1

K4

K3

M2