IDEC FS1A Controller User Manual

Page 75

Advertising
background image

LOGIC

5-27

Chapter 5

When not using the start switch

Auto start

When not detecting the welding of start switch

Manual start

When detecting the welding of start switch

Control start

When connecting multiple emergency stop switches
in series

NOTE: Safety performance depends
on the system configuration.

When not using some inputs

If there are unused safety inputs in S1 to S4,

connect the unused receive terminals to 24V DC
power supply (V+). (Refer to (1))

If there are unused safety inputs in S5 and S6,

connect the unused receive terminals to the
corresponding drive terminals. (Refer to (2))

X16
X17

24V DC

X16
X17

24V DC

S7

24V DC

X16
X17

S7

X10

X11

T10

T11

X12

T12

X13

T13

X

n

X

n+1

T

n

T

n+1

24V DC

X

m

X

m+1

T

m

T

m+1

(1)

(2)


Advertising