LOGIC

5-80

Logic 12A: The logic for apparatus with a two-hand control device

Overview (Logic 12A)

This logic is for using two hand input devices for safety protective measures of production machinery.
Safety outputs perform as dual channel outputs.
This logic enables the connection of 2 dual channel direct opening inputs, 1 input device for
two-hand control (2 dual channel NO/NC inputs), and 2 dual channel safety inputs.

Safety
output 2

System runs

Safety input 1

Safety input 3

Safety input 4

Safety input 2

Safety input 5-6

System
stops

Safety output 1

Safety
output 1

Safety
output 2

Logic 12A

Emergency
stop switch

Safety switch

Two hand

control switch

Safety light
curtain

(PNP type)

Operation example (Logic 12A)

Press!

System runs

Safety
output 2

Safety input 1

Safety input 3

Safety input 4

Safety input 2

Safety input 5-6

Safety output 1

System

runs

Press!

Beams

Safety input 4

Safety output 1

Safety input 3

Safety input 2

Safety input 5-6

Safety input 1

System
stops

Safety
output 2

blocked!

System stops