LOGIC

5-121

Chapter 5

Logic circuit (logic 12d)

Y0

T4, X4, T5, X5

T6, X6, T7, X7

X10, X11

T2, X2, T3, X3

T0, X0, T1, X1

T14, X14

T15, X15

X12

X13

Y1

Y2

Y3

Safety output 1

Safety output 2

Safety input 3

Safety input 2

Safety input 1

Safety input 5

Safety input 4

Start input 1

Start input 2

External device
monitor 2

External device
monitor 1

&

=2k+1

OS1

X16

X17

Control input 1

Control input 2

&

&

S1

S2

S3

S4

Dual Channel

Direct Opening

Dual Channel

D

ependent

Dual Channel

D

ependent

Dual Channel

D

ependent

Dual Channel Safety

Single Channel

Monitor

Single Channel

Monitor

Single Channel

Monitor

Single Channel

Monitor

External Device

Monitor

EDM

External Device

Monitor

EDM

Control

Start

Control

Hold

Trigger

Self-hold

function

Self-hold

function circuit 1

Hold

EDM

OSSD

Hold

EDM

OSSD

with

Off delay

Monitor output for safety input

Monitor output for safety output

S2

S1

Y17

S4

S3

Y20

Safety output 1
monitor

Safety output 2
monitor

Note1:
Safety output 2 monitor turns OFF
immediately independent of OFF-delay
time.

(Note1)

&

&

X1

X0

Y4

X3

X2

Y5

X5

X4

Y6

X7

X6

Y7

X11

X10

Y10

Safety input 1
monitor

Safety input 2
monitor

Safety input 3
monitor

Safety input 4
monitor

Safety input 5
monitor

&

&

&

&

&

OS1

Y13

Y2,Y3

&

Y12

Y0,Y1

(Note2)

Logic function monitor
output 1

Logic function monitor
output 2

(Note3)

Note2:
When both safety input 2 and 3 are ON,
Logic function monitor output 1 turns OFF.
When either safety input 2 or 3 is OFF or ERROR is detected,
Logic function montior output 1 turns ON.

Note3:
When both safety input 4 and 5 are ON,
Logic function monitor output 2 turns OFF.
When either safety input 4 or 5 is OFF or ERROR is detected,
Logic function monitor output 2 turns ON.

Monitor output for logic